Ideal Buck and Boost Worksheet
Estimate ideal CCM duty cycle, inductor ripple and capacitor ripple.
Processing stays in your browser. Ideal continuous-conduction approximations only. Excludes ESR, efficiency, thermal limits, switching losses, device ratings and feedback stability. A failed CCM check means these equations are outside their assumed regime.
How to use the ideal buck and boost worksheet
Start with the supplied example and review converter topology, input voltage v, output voltage v, output current a, switching frequency hz, inductance µh, output capacitance µf. Replace it with your own data, choose Calculate, and check the result against the method and limits below. Copy or download only after review; edits clear the previous output.
How the tool works
Buck duty is Vout/Vin; boost duty is 1−Vin/Vout. Use inductor voltage-time balance for ripple and ideal capacitor charge balance for output ripple. Compare average current with half the ripple to check the CCM assumption.
Worked example
View the example inputs
- Converter topology
- Buck
- Input voltage V
- 12
- Output voltage V
- 5
- Output current A
- 2
- Switching frequency Hz
- 100000
- Inductance µH
- 47
- Output capacitance µF
- 100
The default buck has duty 5/12. Its inductor ripple is approximately 0.621 A peak-to-peak at 100 kHz with 47 µH.
Good to know
Ideal continuous-conduction approximations only. Excludes ESR, efficiency, thermal limits, switching losses, device ratings and feedback stability. A failed CCM check means these equations are outside their assumed regime.
Sources and implementation notes
Implemented by DevBricks Technologies. Method notes updated . References describe the underlying format, method or API. Local processing runs on your device. Any public provider queries are described above and start when you run the lookup.
Keep the physical model separate from a build decision
List the physical quantities and convert them to the units shown by the input labels. Record the operating conditions and reference conventions before substituting values. An ideal model can be useful for checking relationships, but loading, tolerances, environmental conditions and component limitations may fall outside it. Start with a small case that can be checked by hand.
Inputs and settings explained
- Converter topology
- Choose the converter topology setting that matches your task. Available choices: Buck; Boost. The supplied example selects Buck. Compare the result after changing this setting; the options describe different operations or conventions.
- Input voltage V
- Enter a numeric value for input voltage v, using the units and bounds indicated by the label and method notes. The demonstration uses 12. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
12
- Output voltage V
- Enter a numeric value for output voltage v, using the units and bounds indicated by the label and method notes. The demonstration uses 5. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
5
- Output current A
- Enter a numeric value for output current a, using the units and bounds indicated by the label and method notes. The demonstration uses 2. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
2
- Switching frequency Hz
- Enter a numeric value for switching frequency hz, using the units and bounds indicated by the label and method notes. The demonstration uses 100000. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
100000
- Inductance µH
- Enter a numeric value for inductance µh, using the units and bounds indicated by the label and method notes. The demonstration uses 47. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
47
- Output capacitance µF
- Enter a numeric value for output capacitance µf, using the units and bounds indicated by the label and method notes. The demonstration uses 100. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
100
How to review the result
Check dimensions, signs and limiting behavior rather than relying on the apparent precision of the answer. Compare the calculation with the relevant datasheet, measurement or established design procedure for the actual system. If an assumption is violated, use a different analysis instead of interpreting the number as a safe operating recommendation. For signals, sample rate, normalization and feedback-sign conventions are part of the definition of the result.
- Confirm input units, reference values and the operating regime required by the model.
- Inspect component ratings, tolerances and loading separately from an ideal calculation.
- Validate a proposed design with appropriate measurements and qualified review.
Common questions about this workflow
Does a calculated value establish that a circuit or structure is safe?
No. The calculation covers its stated model and supplied inputs. Safety, compliance, manufacturing tolerances and fault conditions require the checks appropriate to the actual application.
Why does a measurement differ from the ideal result?
Real components and environments introduce effects that a simplified model may omit. Check units, measurement setup, loading and operating conditions first, then determine whether the model needs additional terms or a different regime.