HomeSignals & electronicsSeries RLC Resonance and Impedance

Series RLC Resonance and Impedance

Calculate ideal series resonance, Q, bandwidth and impedance at one frequency.

Processing stays in your browser. Uses ideal linear components and positive resistance. Parasitics, frequency-dependent loss, self-resonance, component tolerance, power and voltage ratings are not modeled.

How to use the series rlc resonance and impedance

Start with the supplied example and review series resistance ω, inductance mh, capacitance nf, evaluation frequency hz. Replace it with your own data, choose Calculate, and check the result against the method and limits below. Copy or download only after review; edits clear the previous output.

How the tool works

Convert mH and nF into SI units. Series reactance is ωL−1/(ωC), resonance is 1/(2π√LC), Q is √(L/C)/R and bandwidth is R/(2πL). Use atan2 for impedance phase.

Worked example

View the example inputs
Series resistance Ω
10
Inductance mH
10
Capacitance nF
100
Evaluation frequency Hz
5000

A 10 mH inductor and 100 nF capacitor resonate at approximately 5,032.9 Hz. At resonance the ideal series impedance is the resistance.

Good to know

Uses ideal linear components and positive resistance. Parasitics, frequency-dependent loss, self-resonance, component tolerance, power and voltage ratings are not modeled.

Sources and implementation notes

Implemented by DevBricks Technologies. Method notes updated . References describe the underlying format, method or API. Local processing runs on your device. Any public provider queries are described above and start when you run the lookup.

Keep the physical model separate from a build decision

List the physical quantities and convert them to the units shown by the input labels. Record the operating conditions and reference conventions before substituting values. An ideal model can be useful for checking relationships, but loading, tolerances, environmental conditions and component limitations may fall outside it. Start with a small case that can be checked by hand.

Inputs and settings explained

Series resistance Ω
Enter a numeric value for series resistance ω, using the units and bounds indicated by the label and method notes. The demonstration uses 10. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
10
Inductance mH
Enter a numeric value for inductance mh, using the units and bounds indicated by the label and method notes. The demonstration uses 10. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
10
Capacitance nF
Enter a numeric value for capacitance nf, using the units and bounds indicated by the label and method notes. The demonstration uses 100. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
100
Evaluation frequency Hz
Enter a numeric value for evaluation frequency hz, using the units and bounds indicated by the label and method notes. The demonstration uses 5000. Check signs and scale before calculating; a percentage, fraction and whole-number count have different meanings.
See the demonstration value
5000

How to review the result

Check dimensions, signs and limiting behavior rather than relying on the apparent precision of the answer. Compare the calculation with the relevant datasheet, measurement or established design procedure for the actual system. If an assumption is violated, use a different analysis instead of interpreting the number as a safe operating recommendation. For signals, sample rate, normalization and feedback-sign conventions are part of the definition of the result.

  • Confirm input units, reference values and the operating regime required by the model.
  • Inspect component ratings, tolerances and loading separately from an ideal calculation.
  • Validate a proposed design with appropriate measurements and qualified review.

Common questions about this workflow

Does a calculated value establish that a circuit or structure is safe?

No. The calculation covers its stated model and supplied inputs. Safety, compliance, manufacturing tolerances and fault conditions require the checks appropriate to the actual application.

Why does a measurement differ from the ideal result?

Real components and environments introduce effects that a simplified model may omit. Check units, measurement setup, loading and operating conditions first, then determine whether the model needs additional terms or a different regime.

Built by DevBricks Technologies. Found an unexpected result in Series RLC Resonance and Impedance? Report a reproducible example with the tool URL, settings and a small sample that contains no private information.